|
Laying cables in ducts - Cable blow-in systems
|
|
|
Effective, cost-efficient and absolutely
gentle with cables, the laying of telecommunications cables in ducts
using the LANCIER blow-in systems.
Even copper cables of up to 40 mm diameter are done with no problem
and with high speed, in the course of which only light pulling forces
far below the permissible values are exerted on the cable. A standard site
compressor is the only ancillary unit you need. The cable blowing systems
from LANCIER CABLE are convincing because of the ease of handling
as well as their reliability and high mobility.
|
|
|
| |
|
|
| |
FIBERCAT
|
- Drive chains, fitted with plastic pads, take care of the cable
- The upper chain can be pneumatically lifted up and down
- Both drive chains are driven by a pneumatic motor
- Stable aluminium frame construction
|
 |
More Information |
|
|
FIBERWHEEL
|
- Two roller pairs with knurled surface guarantee an excellent
close linkage to the cable
- The upper wheel can manually be moved up and down
- Both roller pairs are driven by a pneumatic motor
- Stable aluminium frame construction
|
 |
More information |
|
|
POWERWHEEL
|
- Four knurled drive wheels guarantee an excellent close linkage
to the cable
- One drive wheel pair can manually be moved to take up cable
of different diameters
- All drive wheels are driven by two hydraulic motors
- Stable aluminium frame construction
|
 |
more information |
|
|
HYDROCAT
|
- Drive chains, fitted with plastic pads, take care of the cable
- The upper chain can be pneumatically lifted up and down
- Both drive chains are driven by a pneumatic motor
- Stable aluminium frame construction
|
 |
More information |
|
|
MICROCAT
|
- Drive belts with soft surface take care of the cable
- The upper drive belt can manually be moved up and down
- Both drive belts are driven by two powerfull pneumatic motors
- Stable aluminium frame construction
|
 |
More information |
|
|
MICROWHEEL
|
- Wheels with knurled surface transport the cable forward
- The upper wheel can manually be moved up and down
- Both wheels are driven by two powerful pneumatic motors
- Stable aluminium frame construction
|
 |
More information |
|
|
MINICAT
|
- Gentle cable handling due to drive belts or wheel pairs.
- Regulation of pushing force by pressure control valve.
- Both top and bottom drive belts are driven.
- Usable for many standard micro cable diameters.
- Electronic display for blowing speed and length.
|
 |
More information |
|
|
ACCESSORIES

Pulling Grip

Sleeve piston

Cable lubricant
|
| Article |
Order-no. |
| Sleeve piston for internal bore
diam. |
| 28 mm |
57482 |
| 32 mm |
64627 |
| 35 mm |
57483 |
| 40 mm |
57484 |
|
| Cable grip for cable diam. |
| 6-12 mm (black) |
40883 |
| 12-19 mm (red) |
40884 |
| 19-25 mm (green) |
40885 |
| 25-33 mm (white) |
52468 |
|
| Cutter for PE ducts |
68069 |
| Spare knife for cutter |
47600 |
|
| Lubricant GLISS F |
55429 |
|
|


Duct-cutter |
|
Lubricant 5000 for micro-cable laying
|
- Lubricant for blowing micro-cables into small diameter microducts
- Allows for very low cable friction at extremely low coating levels
|
 |
More Information |
|
Ratchet PE-duct cutter

|
|
- Cuts off PE-cable ducts right-angled
- Cables inside the duct are not damaged during cutting
|
 |
More
Information |
|
|
Cable
Booster

|
|
- For the laying of short cable length
- Extension of the blow-in length
- Applicable as stand alone unit or in cascade with another cable
blowing machine
|
 |
More
Information |
|
|
Y-piece

|
|
- Insertion of an additional cable or micro duct into an already occupied duct
- Laying of two cables in only one empty duct at the same time
|
 |
More
information |
|
|
Air-Cooler

|
|
- Can be set-up between compressor and cable-pusher
- High cooling efficiency 7°C above ambient temperatur
- Low loss of flow
|
 |
Technical
Data |
|
|
Injection
pump

|
|
- Optimum distribution of lubricant (e.g. Gliss F) throughout
the cable length
- Pneumatic driving system
|
 |
More
information |
|
|
Lubricator for mini ducts

|
|
|
Exact
400 localization equipment

|
|
| for duct calibration |
- Calibration of different duct diameters
- Exact localization of the probe
- Search for active cables
- Search for inactive metallic leads using an attachment
- Audible and visual indication of signal intensity
|
 |
More
information |
|
Leakage Test Set

|
|
| for PE-ducts |
- Equipped with pressure regulator
- Comprehensive range of accessories included
- A pressure measuring and recording device can be connected
|
 |
More information |
|
|
Coiling
apparatus KARUSSELL
|
Laying cables in the figure of eight is out!
|
Save time and cost when blowing in cables
in two directions or blowing in longer cable lengths. Instead
of laboriously laying the cable in figures of eight or looping it you simply
coil the cable into the KARUSSELL using the blowing-in equipment (for
example FIBERCAT, FIBERWHEEL or HYDROCAT). As soon as the end of the cable
is reached you begin the blowing-in process into the other direction (the
second empty duct).
|

|
| Coiling apparatus KARUSSELL |
- twist- and friction-free cable guidance
- high capacity of cable take-up
- space saving dismountable
- installation is a matter of minutes, no tools
|
 |
More information |
|

|
| Coiling apparatus Mini-KARUSSELL |
- twist- and friction-free cable guidance
- high capacity of cable take-up
- space saving dismountable
- installation is a matter of minutes, no tools
|
 |
More information |
|
|